CFPMS - WHITE ODORLESS ALKYD, G1C509, SEMIGLOSS ENAMEL
- MSDS: CFPMS
- Manufacturer: GARDO INTERNATIONAL INC
- Product Name: WHITE ODORLESS ALKYD, G1C509, SEMIGLOSS ENAMEL
- National Stock Number: 8010-00N079581
Product Identification
Product ID:WHITE ODORLESS ALKYD, G1C509, SEMIGLOSS ENAMEL
MSDS Date:01/11/1993
FSC:8010
NIIN:00N079581
MSDS Number: CFPMS
Responsible Party
HAMPTON, VA 23669
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 804-722-9155
Preparer: B. GARDIER
Cage: 07HP7
Contractor
Telephone: 804-722-9155
Cage: 07HP7
Ingredients
2 @ 68F.
CAS: 8052-41-3
RTECS: WJ8925000
Fraction By Weight: <31%
OSHA PEL 500 PPM
ACGIH TLV: 100 PPM
TITANIUM OXIDE; (TITANIUM DIOXIDE)
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: <16%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
COATING & MATERIAL - 4.05
RTECS: 9999999VO
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IRRIT OF SKIN, EYES, MUC MEMBS,
DRYING, DEFAT. AVOID INGEST & BRTHG OF VAPS. INHAL:EXCESSIVE INHAL
OF VAPS CAN CAUSE NASAL & RESP IRRIT, DIZZ, FATG, NAUS, HDCH, POSS
UNCON & EVEN ASPHY. EYE CONT :CAN CAUSE SEV IRRIT, REDNESS,
TEARING,BLURRED VISION. SKIN CONT:PRLNG/RPTD CONT W/PROD MAY CAUSE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:IRRIT. SKIN ABSORPTION:MAY POTNTLY
CONTRIBUTE TO OVERALL EXPOS TO THIS MATL. APPROP MEASURES SHOULD BE
TAKEN TO PVNT ABSORPTION SO THAT TLV NOT INVALIDATED. INGEST:CAN
CAUSE GI IRRIT, NAUS, V OMIT & DIARR. ASPIR OF MATL INTO LUNGS CAN
CAUSE CHEM PNEUM, WHICH CAN BE FATAL. CHRONIC:EYE, LIVER, KIDNEY &
(SUPDAT)
Medical Cond Aggravated by Exposure:MAY PROVOKE ASTHMATIC RESPONSE IN
PERSONS W/ASTHMA WHO ARE SENSITIVE TO AIRWAY IRRITANT.
First Aid
First Aid:SKIN:WASH W/COPIOUS QUANTITIES OF WATER. EYES:WASH W/COPIOUS
QUANTITIES OF WATER FOR AT LEAST 15 MINUTES, CONTACT MD IF SPILLED
IN EYES. INGEST:DO NOT INDUCE VOMITING, KEEP PERSON WARM, QUIET &
CONTAC T MD. INHAL:REMOVE PERSON TO FRESH AIR.GIVE OXYGEN IF
BREATHING DIFFICULT; GIVE ARTIFICIAL RESPIRATION IF BREATHING
STOPS. KEEP PERSON WARM & GET MEDICAL HELP.
Fire Fighting
Flash Point Method:PMCC
Flash Point:>100F,>38C
Lower Limits:1.4%
Upper Limits:11.2%
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:VAPS ARE HVR/AIR & MAY TRAVEL ALONG
GROUND/BE MOVED BY VENT & IGNITED BY HEAT, PILOT LIGHTS, OTHER
FLAMES & IGNIT SOURCES AT LOCATIONS DIST FROM MATL (SUPDAT)
Accidental Release
Spill Release Procedures:DIKE UP & CONTAIN SPILL W/INERT MATERIAL, MOP
UP & PLACE MATERIAL INTO CONTAINERS. PREVENT RUN-OFF TO SEWER,
STREAMS. NOTIFY AUTHORITIES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE OR USE IN HIGH
TEMPERATURE AREAS OR NEAR HEAT, SPARKS OR FLAME. KEEP CLOSURE TIGHT
& CONTAINER UPRIGHT TO PREVENT LEAKAGE.
Other Precautions:STORE ONLY IN WELL VENTED AREAS. AVOID CONTACT WITH
OR BREATHING OF VAPS RELEASED DURING CURING PROCESS. DO NOT TAKE
INTERNALLY. AVOID CONTACT W/SKIN & EYES. AVOID BREATHING OF
VAPS/SPRAY MISTS. ALL H AZ PRECS GIVEN IN MSDS MUST BE OBSERVED.
Exposure Controls
Respiratory Protection:IF TLV OF PROD/ANY COMPONENT IS EXCEEDED, A
NIOSH APPRVD AIR SUPPLIED RESP IS ADVISED IN ABSENCE OF PROPER
ENVIRON CONTROL. OSHA REGS ALSO PERMIT OTHER NIOSH APPRVD RESPS
UNDER SPECIFIED CNDTNS (SEE S FTY EQUIP SUPPLIER).
ENGINEERING(SUPDAT)
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL &/OR LOCAL EXHAUST)
VENTILATION TO MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:RESISTANT GLOVES SUCH AS NITRILE RUBBER.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
SHOWER . TO PREVENT RPTD/PRLNG SKIN CONT, WEAR IMPERVIOUS CLOTHING
& BOOTS.
Work Hygienic Practices:WASH HANDS BEFORE EATING, SMOKING OR USING
WASHROOM.
Supplemental Safety and Health
EXPLO HAZ:HANDLING POINT. EFTS OF OVEREXP:CENTRAL NERVOUS SYSTEM DAMAGE
MAY OCCUR. WASTE DISP METH:STATE & FEDERAL REGULATIONS. RESP
PROT:OR ADMINISTRATIVE CONTROLS SHOULD BE IMPLEMENTED TO REDUCE EXP
OSURE.
Chemical Properties
Boiling Pt:B.P. Text:243F,117C
Vapor Pres:SEE ING 1
Vapor Density:HVR/AIR
Spec Gravity:1.2 (H*2O=1)
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NOT SOLUBLE
Appearance and Odor:GREEN VISCOUS LIQUIDS W/MINERAL SPIRIT ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NEVER USE WELDING/CUTTING TORCH ON/NEAR
DRUMS (EVEN EMPTY) BECAUSE PRODUCT (EVEN JUST RESIDUE) CAN IGNITE
EXPLOSIVELY.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:SM SPILL:ALLOW VOLAT PORTION TO EVAP IN HOOD.
ALLOW SUFFICIENT TIME FOR VAPS TO COMPLETELY CLEAR HOOD DUCT WORK.
DISP OF REMAINING MATL I/A/W APPLIC REGS. LG SPILL:DESTROY BY LIQ
INCIN. CONTAM ABSORB MAY BE DEPOSITED IN LANDFILL I/A/W
LOC,(SUPDAT)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.